Optical Fiber Burial Unfilled Cable - OBUC

 

Application

  Direct Burial Outdoor cable

In Course Environmental

In Areas with Rodents

Features

 Single-Layer, Stranded construction Up to

144 Fibers Corrugated steel tape as

protection against rodent and mechanical

damage Low weight & clean installation

V.S jelly filled cables


 
  • Possibilities
  • Technical Specifications
  • Description
  • key words
  • User Comments

 Available with LSZH or other jacket for flame retardant or any other features Available with special Design according to the customer request Delivery length upon customer request Other color coding is available according to the customer request

CONSTRUCTION:

 

Specification

Recommended

Standard

IEC 794-1, ITU-T G652D, ITU-T G655

Construction

Design Type

1-layer cable core /water blocking tape /steel tape as armor/2jackets

Number of Fiber

4 ... 144

Optical Fiber

Type

Single Mode LWP, NZDSF

Color

1)white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) violet 9) orange 10) pink 11) gray 12) natural

Central strength Member

Material

FRP

Diameter

Nom. 2.7 mm that will up coat to suitable diameter if required and will bind with water swell able yarn

Loose Tube

 

Tube Material

PBT

Filling Compound

Thixotropic jelly compound

Assembly

6 or 12 optical fibers will have placed loosely into a jelly-filled thermoplastic tube

Diameter

Nom. 2.4 or 2.6 mm

Number of Fibers

6, 12

Color

 

1)white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) violet 9) orange 10) pink 11) gray 12) natural

Stranding

6…12 loose tubes (and if necessary fillers) will be stranded around the strength member that is bound with water swell able yarn and will wrapped with a layer of Water blocking tape

Core Wrapping

Water blocking tape

Inner Sheath (Optional)

Material

Polyethylene colored black

Thickness

Nom. 1.4 mm

Armoring

Copolymer coated corrugated steel tape

Ripcord

2 opposite Ripcords under each jackets (totally 4)

Reinforcement

None

Outer Sheath

Material

Polyethylene colored black

Thickness

Nom. 2 mm

Cable Diameter

Nom. 17.2 …. 21.5 mm

Cable Weight

Nom. 284 … 430 Kg/Km

 

PERFORMANCE:

 

Specification

Recommended

Mechanical Characteristics

Tensile Strength

2.7 KN

Min. Bending Radius

Installation

15*D (Cable Diameter)

Operation

20*D (Cable Diameter)

Environmental Characteristics

Temperature

Installation

-30~+70 °C

Operation

-40~+80 °C

Performance Test

Compression

EIA/TIA 455-41-A

Pulling

IEC-794-1-E1

Water penetration

FOTP-82

Kink

IEC-794-1-E10

Cable Flexing

EIA/TIA-455-104-A

Twist

EIA/TIA-455-85

Repeated Impact

EIA/TIA-455-25-C

Temperature Cycling

IEC-794-1-F1

Low or high temperature bend

EIA/TIA 455-37

Knot

EIA/TIA 455-87

 

Description

  Post a comment