With glass yarn elements as rodent
protection Available with LSZH or other
jacket for flame retardant or any other
features Available with special Design
according to the customer request
Delivery length is as customer request.
CONSTRUCTION:
Specification |
Recommended |
||
Standard |
IEC 794-1, ITU-T G652D, G655 |
||
Construction |
|||
Design Type |
1-layer cable core /polyester tape /Aramid yarn as strength member/1jacket |
||
Number of Fiber |
12 … 72 |
||
Optical Fiber |
Type |
Single mode LWP, NZDSF |
|
Color |
1)white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) |
||
Central strength Member |
Material |
FRP |
|
Diameter |
Nom. 2.5 mm that will up coat to suitable diameter if required |
||
Loose Tube
|
Tube Material |
PBT |
|
Filling Compound |
Thixotropic jelly compound |
||
Assembly |
2-12 optical fibers will have placed loosely into a jelly-filled thermoplastic tube
|
||
Diameter |
Nom. 2.4 mm |
||
Number of Fibers |
2-12 |
||
Color |
1)white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) violet 9) orange 10) pink 11) gray 12) natural |
||
Stranding |
2 to 12 loose tubes (and if necessary fillers) will be stranded around the strength member and will filled with jelly and wrapped with a layer of polyester tape. over the tape there are Aramid yarns as intermediate strength member |
||
Core Wrapping |
Polyester tape |
||
Inner Sheath (Optional) |
Material |
…. |
|
Thickness |
…. |
||
Armoring |
None |
||
Ripcord |
2 opposite Ripcords under jacket |
||
Reinforcement |
Aramid yarns |
||
Outer Sheath |
Material |
Polyethylene colored black |
|
Thickness |
Nom. 2 mm |
||
Cable Diameter |
Nom. 12.2…17.2 mm |
||
Cable Weight |
Nom. 0.107…0.209 kg/m |
PERFORMANCE:
Specification |
Recommended |
||
Mechanical Characteristics |
|||
Tensile Strength |
|
3 KN |
|
Min. Bending Radius |
Installation |
15*D (Cable Diameter) |
|
Operation |
20*D (Cable Diameter) |
||
Environmental Characteristics |
|||
Temperature |
Installation |
-30°C to +70 °C |
|
Operation |
-40°C to +80 °C |
||
Performance Test |
|||
Compression |
EIA/TIA 455-41-A |
Pulling |
IEC-794-1-E1 |
Water Penetration |
FOTP-82 |
Kink |
IEC-794-1-E10 |
Cable Flexing |
EIA/TIA-455-104-A |
Twist |
EIA/TIA 455-85 |
Repeated Impact |
EIA/TIA-455-25-C |
Temperature Cycling |
IEC-794-1-F1 |
Low or high temperature bend |
EIA/TIA-455-37 |
|
|
Description