Available with LSZH or other jacket for
flame retardant or any other features
Available with special Design according to
the customer request Delivery length
upon customer request. Other color
coding is available according to the
customer request
CONSTRUCTION:
Specification |
Recommended |
|||
Standard |
IEC 794-1, ITU-T G652D, ITU-T G655 |
|||
Construction |
||||
Design Type |
1-layer cable core /water blocking tape /steel tape as armor/Messenger wire/2jackets |
|||
Number of Fiber |
4…36 |
|||
Optical Fiber |
Type |
Single Mode LWP, NZDSF |
||
Color |
1)white 2) red 3) Green 4) blue5) yellow6) black |
|||
Central strength Member |
Material |
FRP |
||
Diameter |
Nom. 1.7 or 2.5 mm that will up coat to suitable diameter if required and will bind with water swell able yarn |
|||
Loose Tube
|
Tube Material |
PBT |
||
Filling Compound |
Thixotropic jelly compound |
|||
Assembly |
4 or 6 optical fibers will have placed loosely into a jelly-filled thermoplastic tube |
|||
Diameter |
Nom. 1.8 to 2.4 mm |
|||
Number of Fibers |
4 … 6 |
|||
Color |
|
1)white 2) red 3) Green 4) blue5) yellow6) black |
||
Stranding |
1-6 loose tubes (and if necessary fillers) will be stranded around the strength member that is bound with water swell able yarn and will wrapped with a layer of Water blocking tape |
|||
Core Wrapping |
Water blocking tape |
|||
Inner Sheath (Optional) |
Material |
Polyethylene colored black |
||
Thickness |
Nom. 1.4 mm |
|||
Armoring |
Copolymer coated corrugated steel tape |
|||
Messenger Wire |
Material |
7 stranded galvanized steel wires |
||
Diameter |
(6*1.2) +1.2 |
|||
Web Dimensions |
Height |
3±0.5mm |
||
Width |
2.5±0.5mm |
|||
Ripcord |
2 opposite Ripcords under each jackets (totally 2) |
|||
Reinforcement |
None |
|||
Outer Sheath |
Material |
Polyethylene colored black |
||
Thickness |
Nom. 2.0 mm |
|||
Cable Diameter |
Nom. 14.1 …. 16.2 mm |
|||
Cable Weight |
Nom. 0.293 … 0.350 kg/m |
PERFORMANCE:
Specification |
Recommended |
|||
Mechanical Characteristics |
||||
Tensile Strength |
6 KN |
|||
Min. Bending Radius |
Installation |
15*D (Cable Diameter) |
||
Operation |
20*D (Cable Diameter) |
|||
Environmental Characteristics |
||||
Temperature |
Installation |
-30°C to +70 °C |
||
Operation |
-40°C to +80 °C |
|||
Performance Test |
||||
Compression |
FOTP-41 |
Pulling |
IEC 794-1-E1 |
|
Water penetration |
FOTP-82 |
Kink |
IEC-794-1-E10 |
|
Cable Flexing |
EIA/TIA-455-104-A |
Twist |
FOTP-85 |
|
Repeated Impact |
FOTP-25 |
Temperature Cycling |
FOTP-3 |
|
Low or high temperature bend |
FOTP-37 |
|
Description