Optical Fiber Self Support Cable - OSSC SJ

 

Application

 Outdoor cable Aerial installation along

wooden or concrete poles Suitable for

railway or telecommunication lines

Suitable for Jungle area (gun shot

protection) Not used near high and

Medium voltage power lines Ideal for rural

and urban area installation General

telecommunication application

 

Features

Single-Layer, Stranded construction Use of 7

stranded steel wires with 1.2 or 0.9 mm

diameter Dry and clean construction

without filling jelly High tensile Strength

clean installation V.S jelly filled cables

 


 
  • Possibilities
  • Technical Specifications
  • Description
  • key words
  • User Comments

 Available with LSZH or other jacket for

flame retardant or any other features

Available with special Design according to

the customer request Delivery length 

upon customer request. Other color

coding is available according to the

customer request

CONSTRUCTION:

 

Specification

Recommended

Standard

IEC 794-1, ITU-T G652D, ITU-T G655

Construction

Design Type

1-layer cable core /water blocking tape /steel tape as armor/Messenger wire/2jackets

Number of Fiber

4…36

Optical Fiber

Type

Single Mode LWP, NZDSF

Color

1)white 2) red 3) Green 4) blue5) yellow6) black

Central strength Member

Material

FRP

Diameter

Nom. 1.7 or 2.3 mm that will up coat to suitable diameter if required and will bind with water swell able yarn

Loose Tube

 

Tube Material

PBT

Filling Compound

Thixotropic jelly compound

Assembly

4 or 6 optical fibers will have placed loosely into a jelly-filled thermoplastic tube

Diameter

Nom. 1.8 to 2.4 mm

Number of Fibers

4 … 6

Color

 

1)white 2) red 3) Green 4) blue5) yellow6) black

Stranding

6 loose tubes (and if necessary fillers) will be stranded around the strength member that is bound with water swell able yarn and will wrapped with a layer of Water blocking tape

Core Wrapping

Water blocking tape

Inner Sheath (Optional)

Material

   ..........

 

Thickness

   ..........

 

Armoring

    none

 

Outer Sheath

Material

Polyethylene colored black

Thickness

Nom. 2 mm 

Inner Sheath (Optional)

Material 

   ........

 

Thickness

  .........

 

 Ripcord

2 opposite Ripcords under jacket

Reinforcement

Aramid yarns

Outer Sheath

Material

Polyethylene colored black

Thickness

Nom. 2 mm

Cable Diameter

Nom. 12.2…17.2 mm

Cable Weight

Nom. 0.107…0.209 kg/m

 

PERFORMANCE:

 

Specification

Recommended

Mechanical Characteristics

Tensile Strength

3 KN

Min. Bending Radius

Installation

15*D (Cable Diameter)

Operation

20*D (Cable Diameter)

Environmental Characteristics

Temperature

Installation

-30°C to +70 °C

Operation

-40°C to +80 °C

Performance Test

Compression

EIA/TIA 455-41-A

Pulling

IEC 794-1-E1

Water penetration

FOTP-82

Kink

IEC-794-1-E10

Cable Flexing

EIA/TIA-455-104-A

Twist

EIA/TIA 455-85

Repeated Impact

EIA/TIA-455-25-C

Temperature Cycling

IEC-794-1-F1

Low or high temperature bend

EIA/TIA-455-37

 

 