Available with LSZH or other jacket for
flame retardant or any other features
Available with special Design according to
the customer request Delivery length
upon customer request. Other color
coding is available according to the
customer request
CONSTRUCTION:
Specification |
Recommended |
|||
Standard |
IEC 794-1, ITU-T G652D, ITU-T G655 |
|||
Construction |
||||
Design Type |
1-layer cable core /water blocking tape /steel tape as armor/Messenger wire/2jackets |
|||
Number of Fiber |
4…36 |
|||
Optical Fiber |
Type |
Single Mode LWP, NZDSF |
||
Color |
1)white 2) red 3) Green 4) blue5) yellow6) black |
|||
Central strength Member |
Material |
FRP |
||
Diameter |
Nom. 1.7 or 2.3 mm that will up coat to suitable diameter if required and will bind with water swell able yarn |
|||
Loose Tube
|
Tube Material |
PBT |
||
Filling Compound |
Thixotropic jelly compound |
|||
Assembly |
4 or 6 optical fibers will have placed loosely into a jelly-filled thermoplastic tube |
|||
Diameter |
Nom. 1.8 to 2.4 mm |
|||
Number of Fibers |
4 … 6 |
|||
Color |
|
1)white 2) red 3) Green 4) blue5) yellow6) black |
||
Stranding |
6 loose tubes (and if necessary fillers) will be stranded around the strength member that is bound with water swell able yarn and will wrapped with a layer of Water blocking tape |
|||
Core Wrapping |
Water blocking tape |
|||
Inner Sheath (Optional) |
Material |
..........
|
||
Thickness |
..........
|
|||
Armoring |
none
|
|||
Outer Sheath |
Material |
Polyethylene colored black |
||
Thickness |
Nom. 2 mm |
|||
Inner Sheath (Optional) |
Material |
........
|
||
Thickness |
.........
|
|||
Ripcord |
2 opposite Ripcords under jacket |
|||
Reinforcement |
Aramid yarns |
|||
Outer Sheath |
Material |
Polyethylene colored black |
||
Thickness |
Nom. 2 mm |
|||
Cable Diameter |
Nom. 12.2…17.2 mm |
|||
Cable Weight |
Nom. 0.107…0.209 kg/m |
PERFORMANCE:
Specification |
Recommended |
|||
Mechanical Characteristics |
||||
Tensile Strength |
3 KN |
|||
Min. Bending Radius |
Installation |
15*D (Cable Diameter) |
||
Operation |
20*D (Cable Diameter) |
|||
Environmental Characteristics |
||||
Temperature |
Installation |
-30°C to +70 °C |
||
Operation |
-40°C to +80 °C |
|||
Performance Test |
||||
Compression |
EIA/TIA 455-41-A |
Pulling |
IEC 794-1-E1 |
|
Water penetration |
FOTP-82 |
Kink |
IEC-794-1-E10 |
|
Cable Flexing |
EIA/TIA-455-104-A |
Twist |
EIA/TIA 455-85 |
|
Repeated Impact |
EIA/TIA-455-25-C |
Temperature Cycling |
IEC-794-1-F1 |
|
Low or high temperature bend |
EIA/TIA-455-37 |
|
Description