With glass yarn elements as rodent
protection Available with LSZH or other
jacket for flame retardant or any other
features (Like PVC or …) Available with
special Design according to the customer
request Delivery length upon customer
request. Other color coding is available
according to the customer request
CONSTRUCTION:
Specification |
Recommended |
||
Standard |
IEC 60794-2/ITUT G652D, G651, G657 or any |
||
Construction |
|||
Design Type |
1-layer cable core / Laminated water blocking tape /1jacket |
||
Number of Fiber |
12,24,48,72,96,144 |
||
Optical Fiber |
Type |
SM, NZDSF or any |
|
Color |
(1white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) violent 9) orange 10) pink 11) gray 12) natural |
||
Central strength Member |
Material |
FRP (Normally) |
|
Diameter |
12 to 72 core: Nom. 1.7 mm 96 core: Nom. 2.7 mm 144 core: Nom. 2.5 up coated to 5 mm |
||
Loose Tube
|
Tube Material |
PBT |
|
Filling Compound |
Thixotropic jelly compound |
||
Assembly |
12optical fibers will have placed loosely into a jelly-filled thermoplastic tube |
||
Diameter |
Nom. 1.7 mm |
||
Number of Fibers |
12pcs |
||
Color |
|
1white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) violent 9) orange 10) pink 11) gray 12) natural |
|
Stranding |
6or 8 or 12 loose tubes (and fillers if needed) will be stranded around the strength member and will wrapped with a layer of Water blocking tape |
||
Core Wrapping |
Water blocking tape |
||
Outer Sheath |
Material |
polyethylene colored black |
|
Thickness |
Nom. 0.7 to 0.8 mm |
||
Ripcord |
2opposite Ripcords under the jacket |
||
Reinforcement |
Normally None but available by request |
||
Tensile Strength Min. Bending Radius |
Installation |
700N |
|
Installation |
*15D (Cable Diameter) |
||
Cable Diameter |
12 to 72 core: Approx. 7.0 mm 96 core: Approx. 8.0 mm 144 core: Approx. 10.5 mm |
||
Cable Weight |
Approx. 0.036 to 0.065 kg/m |
PERFORMANCE:
Specification |
Recommended |
||
Mechanical Characteristics |
|||
Tensile Strength |
Installation |
700N |
|
Min. Bending Radius |
Installation |
15*D (Cable Diameter) |
|
Operation |
20*D (Cable Diameter) |
||
Environmental Characteristics |
|||
Temperature |
Installation |
-30°C to +70 °C |
|
Operation |
-40°C to +80 °C |
Description