Conduit Air Core Unnfilled Copper Cable - CUC

 

Application

 Outdoor cable To use in the

telecommunication networks and between

centers and Cabinets suitable for duct

installation Air core Laying in to the cable

tray

Features

 Available by any pairs, form 100 to 2400

pairs suitable for duct installation Air core

Designed 


 
  • Possibilities
  • Technical Specifications
  • Description
  • key words
  • User Comments

Available with LSZH, PE or other jacket for

flame retardant or any other features

Available with special Design according to

the customer request Delivery length

upon customer request Other packing and

color coding is available according to the

customer request

CONSTRUCTION:

 

Specification

Recommended

Standard

TCT 1385 / 10, ASTM D 1535, IEC 247,538

Construction

Design type

1,2 or 3 Layer cable core / polyester tape / Aluminum Shield / 2 jackets

Number of pairs

100 … 2400

Material

Conductor: copper, Insulation: HDPE polyethylene, Inner Sheath: LDPE polyethylene colored black, Outer Sheath: LDPE polyethylene colored black

Aluminum Tape:  Aluminum Polymer Coated

Jacket Thickness

Inner sheath: Nominal Thickness = 1.4 mm, Outer sheath: 1.5 ~ 2.8 mm

Cable Diameter

Nom. 22.5 … 78.5 mm

Cable Weight

Nom. 555 … 8480 kg/km

 

DIMENSION:

 

Final Weight (Kg/Reel)

Nominal Weight (Kg/Km)

Delivery Length (m)

Outer Diameter(mm)

Sheath Thickness(mm)

Size

639

555

1010

22.50

1.8

100 ×2× 0.4

863

763

1010

26.50

2.0

150 ×2× 0.4

1180

960

1010

28.50

2.0

200 ×2× 0.4

1221

1330

760

33.0

2.2

300 ×2× 0.4

950

1700

505

37.00

2.3

400 ×2× 0.4

1253

2065

505

40.50

2.3

500 ×2× 0.4

711

2420

255

43.50

2.5

600 ×2× 0.4

1181

3805

255

54.00

2.7

1000 ×2× 0.4

1350

4475

255

58.00

2.7

1200 ×2× 0.4

1967

6485

255

69.00

2.9

1800 ×2× 0.4

2511

8480

255

78.50

3.1

2400 ×2× 0.4

 

 

 

 

 

 

1290

1070

1010

29.50

2.0

100 ×2× 0.6

1349

1500

760

34.50

2.2

150 ×2× 0.6

1178

1915

505

38.50

2.3

200 ×2× 0.6

1685

2710

505

45.00

2.5

300 ×2× 0.6

.

.

.

.

.

.

 

PERFORMANCE:

 

0.6 mm

0.4 mm

UNIT

PARAMETERS

65

147

Ω/km

Max. Ind

Resistance

62

139

Ω/km

Max. Ave

4.5

5

%

Max. Ind

Resistance Unbalance

1.5

2

%

Max. Ave

4.5

2.8

Kv/ 3sec

Conductor to Conductor

Dielectric

Strength

15

15

Kv/ 3sec

Conductor to Ground

57

57

Nf/km

Max. Ind

Mutual

52±2

52±2

Nf/km

Ave

Capacitance

2625

2625

Pf/km

Pair to ground Max.Ind

Capacitance Unbalance

574

574

Pf/km

Max. Ave Pair to ground

45

45

Pf/km

Max.RMS  Pair to pair 

17.3

25.7

dB/km

Ave 1024 KHz

Attenuation

21.0

31.2

dB/km

Ave 1500 KHz

35

35

dB/km

Worst power-sum 1024

Crosstalk

41

39

dB/km

Mean power-sum 1024

26

26

dB/km

Worst power-sum 3150

32

30

dB/km

Mean power-sum 3150

 

Description:

Conductor diameters of these cables are usually O.4mm up to O.6mm.

Other sizes of customer request are available to product.

  Post a comment