Available with LSZH, PE or other jacket for
flame retardant or any other features
Available with special Design according to
the customer request Delivery length
upon customer request Other packing and
color coding is available according to the
customer request
CONSTRUCTION:
Specification |
Recommended |
Standard |
TCT 1385 / 10, ASTM D 1535, IEC 247,538 |
Construction |
|
Design type |
1,2 or 3 Layer cable core / polyester tape / Aluminum Shield / 2 jackets |
Number of pairs |
100 … 2400 |
Material |
Conductor: copper, Insulation: HDPE polyethylene, Inner Sheath: LDPE polyethylene colored black, Outer Sheath: LDPE polyethylene colored black Aluminum Tape: Aluminum Polymer Coated |
Jacket Thickness |
Inner sheath: Nominal Thickness = 1.4 mm, Outer sheath: 1.5 ~ 2.8 mm |
Cable Diameter |
Nom. 22.5 … 78.5 mm |
Cable Weight |
Nom. 555 … 8480 kg/km |
DIMENSION:
Final Weight (Kg/Reel) |
Nominal Weight (Kg/Km) |
Delivery Length (m) |
Outer Diameter(mm) |
Sheath Thickness(mm) |
Size |
639 |
555 |
1010 |
22.50 |
1.8 |
100 ×2× 0.4 |
863 |
763 |
1010 |
26.50 |
2.0 |
150 ×2× 0.4 |
1180 |
960 |
1010 |
28.50 |
2.0 |
200 ×2× 0.4 |
1221 |
1330 |
760 |
33.0 |
2.2 |
300 ×2× 0.4 |
950 |
1700 |
505 |
37.00 |
2.3 |
400 ×2× 0.4 |
1253 |
2065 |
505 |
40.50 |
2.3 |
500 ×2× 0.4 |
711 |
2420 |
255 |
43.50 |
2.5 |
600 ×2× 0.4 |
1181 |
3805 |
255 |
54.00 |
2.7 |
1000 ×2× 0.4 |
1350 |
4475 |
255 |
58.00 |
2.7 |
1200 ×2× 0.4 |
1967 |
6485 |
255 |
69.00 |
2.9 |
1800 ×2× 0.4 |
2511 |
8480 |
255 |
78.50 |
3.1 |
2400 ×2× 0.4 |
|
|
|
|
|
|
1290 |
1070 |
1010 |
29.50 |
2.0 |
100 ×2× 0.6 |
1349 |
1500 |
760 |
34.50 |
2.2 |
150 ×2× 0.6 |
1178 |
1915 |
505 |
38.50 |
2.3 |
200 ×2× 0.6 |
1685 |
2710 |
505 |
45.00 |
2.5 |
300 ×2× 0.6 |
. |
. |
. |
. |
. |
. |
PERFORMANCE:
0.6 mm |
0.4 mm |
UNIT |
PARAMETERS |
|
65 |
147 |
Ω/km |
Max. Ind |
Resistance |
62 |
139 |
Ω/km |
Max. Ave |
|
4.5 |
5 |
% |
Max. Ind |
Resistance Unbalance |
1.5 |
2 |
% |
Max. Ave |
|
4.5 |
2.8 |
Kv/ 3sec |
Conductor to Conductor |
Dielectric Strength |
15 |
15 |
Kv/ 3sec |
Conductor to Ground |
|
57 |
57 |
Nf/km |
Max. Ind |
Mutual |
52±2 |
52±2 |
Nf/km |
Ave |
Capacitance |
2625 |
2625 |
Pf/km |
Pair to ground Max.Ind |
Capacitance Unbalance |
574 |
574 |
Pf/km |
Max. Ave Pair to ground |
|
45 |
45 |
Pf/km |
Max.RMS Pair to pair |
|
17.3 |
25.7 |
dB/km |
Ave 1024 KHz |
Attenuation |
21.0 |
31.2 |
dB/km |
Ave 1500 KHz |
|
35 |
35 |
dB/km |
Worst power-sum 1024 |
Crosstalk |
41 |
39 |
dB/km |
Mean power-sum 1024 |
|
26 |
26 |
dB/km |
Worst power-sum 3150 |
|
32 |
30 |
dB/km |
Mean power-sum 3150 |
Description:
Conductor diameters of these cables are usually O.4mm up to O.6mm.
Other sizes of customer request are available to product.