Conduit Filled Copper Cable - CFC

 

Application

Outdoor cable To use in the

telecommunication networks and between

centers and Cabinets suitable for duct

installation Water Protected Laying in to

the cable tray

Features

Available by any pairs, form 10 to 600 pairs

suitable for duct installation Filled with jelly

compound 


 
  • Possibilities
  • Technical Specifications
  • Description
  • key words
  • User Comments

Available with LSZH, PE or other jacket for

flame retardant or any other features

Available with special Design according to

the customer request Delivery length

upon customer request Other packing and

color coding is available according to the

customer request

CONSTRUCTION:

 

Specification

Recommended

Standard

TCT 1385 / 10, ASTM D 1535, IEC 247,538

Construction

Design type

1 or 2 Layer cable core / polyester tape / Aluminum Shield / 1 jacket

Number of pairs

10 … 600

Material

Conductor: copper, Insulation: HDPE polyethylene, Sheath: LDPE polyethylene colored black, Aluminum Tape:  Aluminum Polymer Coated

Jacket Thickness

Sheath: Nominal Thickness 1.6 ~ 2.8 mm

Cable Diameter

Nom. 11.0 … 66.5 mm

Cable Weight

Nom. 115 … 6155 kg/km

 

DIMENSION:

 

Final Weight (Kg/Reel)

Nominal Weight (Kg/Km)

Delivery Length (m)

Outer Diameter(mm)

Sheath Thickness(mm)

Size

153

115

1010

11.00

1.8

10 ×2× 0.4

198

160

1010

13.00

1.8

20 ×2× 0.4

248

210

1010

14.50

1.8

30 ×2× 0.4

302

255

1010

16.00

1.8

40 ×2× 0.4

360

300

1010

17.00

1.8

50 ×2× 0.4

469

385

1010

19.50

1.8

70 ×2× 0.4

594

510

1010

22.00

1.8

100 ×2× 0.4

890

790

1010

25.00

1.8

150 ×2× 0.4

1253

1035

1010

28.50

2

200 ×2× 0.4

1345

1495

760

33.50

2.2

300 ×2× 0.4

1198

1955

505

38.00

2.3

400 ×2× 0.4

1423

2405

505

42.50

2.5

500 ×2× 0.4

820

2850

255

46.00

2.6

600 ×2× 0.4

 

218

180

1010

13.50

1.8

10 ×2× 0.6

327

280

1010

16.50

1.8

20 ×2× 0.6

464

380

1010

19.00

1.8

30 ×2× 0.6

.

.

.

.

.

.

 

PERFORMANCE:

 

0.6 mm

0.4 mm

UNIT

PARAMETERS

65

147

Ω/km

Max. Ind

Resistance

62

139

Ω/km

Max. Ave

4.5

5

%

Max. Ind

Resistance Unbalance

1.5

2

%

Max. Ave

3.5

2.8

Kv/ 3sec

Conductor to Conductor

Dielectric

Strength

15

15

Kv/ 3sec

Conductor to Ground

57

57

Nf/km

Max. Ind

Mutual

52±2

52±2

Nf/km

Ave

Capacitance

2625

2625

Pf/km

Pair to ground Max.Ind

Capacitance Unbalance

574

574

Pf/km

Max. Ave Pair to ground

45

45

Pf/km

Max.RMS  Pair to pair 

15.2

23.5

dB/km

Ave 1024 KHz

Attenuation

5.18

25.2

dB/km

Ave 1500 KHz

35

35

dB/km

Worst power-sum 1024

Crosstalk

41

39

dB/km

Mean power-sum 1024

26

26

dB/km

Worst power-sum 3150

32

30

dB/km

Mean power-sum 3150

 

Description:

Conductor diameters of these cables are usually O.4mm up to O.6mm.

Other sizes of customer request are available to product.

  Post a comment